EXTRONIX DIVISION

LOSS MEASUREMENT SYSTEM

CABLE LOSS MEASUREMENT MADE EASY!

 

PECA's Loss Measurement System

LOSS MEASUREMENT

SYSTEM

MODEL LMS-1544

  PECA Inc. , is introducing a Loss Measurement System that is as easy to use as a multimeter.  Certain Baseband LANs specify Attenuative Taps and Splitters in the construction of the network, requiring verification of I/O Port attenuation values.  PECA/Extronix’ LMS-1544, Loss Measurement System consisting of the LMT-1544 Transmitter and the LMR-1544 Receiver  makes the measurement and verification easy and accurate.

The LMS-1544’s transmitter, LMT-1544, is constructed to conveniently connect to the input of the cable network applying the test reference signal throughout the network. The LMT is AC powered to ensure reliable unattended operation.

The LMS-1544’s receiver, LMR-1544, is portable and equipped with rechargeable batteries providing for easy  transporting from I/O tap to I/O tap location.  The LMR is also AC powered for operation and recharging batteries.

Set up and calibration requires only connecting the transmitter to the receiver and adjusting the transmitter output.  From then on, just connect the LMS-1544 to the I/O ports, select the Loss Range and read the meter.

Specifications

ELECTRICAL

 

LMR-1544 Receiver

LMT-1544 Transmitter

Impedance

75 Ohms

75 Ohms

Frequency

1.544 MHz

1.544 MHz

Sensitivity

1.0 mV (0dBmV)

 

Bandwidth

10 Khz @ -6dB

 

Input Range

1.0 mV to 1.0  V

 

Level Accuracy

+/- 0.5dB

+/- 9.5dB

Power Supply

Line or Battery

Operation

117 VAC/ 60 Hz 25 W

Battery Operation,

NiCad Rechargeable, 120 hr.

operation on full charge

Input  117 VAC/60Hz 10

Output 12VDC/300mA

Operating Condition

20 C Optimal 0-60 C

20 C Optimal 0-60 C

Output Level

 

1.0V (Adjustable +/-3dB

 

MECHANICAL

 
LMT-1544
LMR-1544
LMS-1544

Length

4.6”

8”

*

Width

3.1”

6”

*

Height

1.5”

9”

*

Weight

1.5 lbs.

10.5 lbs.

12 lbs.